Gains data model Option

Data tab on Model Options dialog.

Gains data

There are three levels of gains model detail:

 

Note: When using the Lumped Gains model option, Comfort data is not generated because in EnergyPlus the request for comfort calculations is made in the People statement and this is not generated by DesignBuilder when Lumped gains is set.

Important Note: The Detailed gains option is included for legacy models only and may be discontinued in future versions of the software.

Lighting gain units

There are 2 ways to define General lighting gains in DesignBuilder:

 

  1. Watts per m2 - this used to be the default value in versions pre v2.1, where the General lighting gains are defined as W/m2 independent of the required illuminance level. This method has the advantage that the level of gains can clearly be understood by looking at W/m2 values and floor area. However it can cause problems when loading data from lighting templates (where lighting gains are defined in W/m2/100lux) in that if the activity is changed subsequently with a different illuminance requirement, the lighting W/m2 value is not updated. This led to the introduction of the second option.
  2. Watts per m2 per 100lux - the default option in v2.1 and later. Although the units W/m2/100lux may seem quite obscure, this method of defining lighting gains has advantages over using W/m2. Namely that the actual lighting level is associated with the lighting system type without the need to refer to the activity and hence illuminance requirement. So if a particular lighting system type is installed throughout a building but the building has a range of activities, it will usually be possible to enter the lighting W/m2/100lux value once only at building level, set the activity for each zone and still get realistic lighting gains. See General lighting gains for details on the calculation of lighting gains from W/m2/100lux, floor area and illuminance requirements.

Occupancy latent gains

There are 2 ways for the sensible-latent split of occupancy gains to be defined:

 

  1. Dynamic calculation - where the latent fraction of occupancy gains is calculated within EnergyPlus at runtime based on internal temperatures and metabolic rate. In this case the ratio of sensible to total occupancy gain will reduce as the internal temperature in the zone increases and at temperatures much above 30°C all of the occupancy gain will be latent (occupants sweating).
  2. Fixed fraction - where the latent fraction of occupancy gains is constant regardless of internal conditions and defined on the Activity tab under the Occupancy header.

 

Note: The total occupancy gain (sensible + latent) is not affected by this option, only the split of sensible vs latent gain.