Optimisation Design Variable

Accessed from Optimisation and Parametric Analysis Settings dialog

Design Variable

Variable type

Select the variable type from the browse list.

 

Note: All variables are listed for selection regardless of the state of the model so care must be taken to select variables that are appropriate. For example, if the Scheduled natural ventilation model option is used then changes in the % External window opens variable (which only applies to Calculated natural ventilation) won't affect results.

Min value

The lowest value that this numeric design variable can take on. This option is only visible when a numeric variable type has been selected (above).

Max value

The highest value that this numeric design variable can take on. This option is only visible when a numeric variable type has been selected (above).

Step

Not used yet. This option is only visible when a numeric variable type has been selected (above).

Values

Click on the browse button to open a list of components or templates for selection. Items can be selected by checking the appropriate checkboxes.

 

When a template is selected as the variable type, one of the selected templates from the list are loaded in each iteration of the optimisation analysis.

 

This option is only visible when a list variable type has been selected (above).

Target

Target objects

This option allows you to select one or more object(s) to which the variations are to be applied.

 

The object(s) you select here are the places in the model where the variations will actually be applied. Normal model data inheritance rules apply so if you set the building as the target then the change will set for the building but will also inherit down to block, zone, surface and opening levels where appropriate. In this case any hard set data at block or lower levels will prevent inheritance in the normal way.

Key

Variable key

This data is available for variables of the Custom IDF and Custom Script categories. Enter the name of the variable to be used in one or more corresponding DB Erl / EMS <Var, VarName, DefaultValue> statements. The variable key entered here corresponds with the VarName value in the DB Erl script.